According to the requirements of the "Sanitary Standards for Drinking Water" for export water quality monitoring instruments, the company's pipeline water quality analysis system can measure turbidity, residual chlorine/chlorine dioxide, pH, EC, and temperature. It uses RS485 digital interface, TCP/IP, and GPRS/4G for wireless transmission. The ultra-low turbidity analyzer in this analysis system is equipped with a bubble removal device to ensure the accuracy of turbidity measurement; The residual chlorine measurement adopts a three electrode constant voltage residual chlorine electrode, which can achieve residual chlorine measurement of 0-20mg/L. There is no need to add electrolyte inside the electrode, and the maintenance workload is small. The pH value is detected by the glass electrode method; Detecting electrical conductivity in water using graphite two/four electrode method; The whole machine has the characteristics of small size, low maintenance, and low usage cost, making it suitable for situations with tight space.
System Features
Ø Electrode analyzer, the detection process does not require reagents, does not produce secondary pollution, and has a small maintenance workload;
Intelligent self diagnosis, with fault alarm functions such as water shortage and sensor device abnormalities;
Equipped with RS485 output and optional wireless network transmission;
Multi level permission management ensures data security;
Ø 7-inch industrial grade touch screen, making viewing and operation more convenient;
|
parameter |
Technical Specifications |
|
|
measurement parameters |
pH, Turbidity, residual chlorine, EC/TDS、 temperature |
|
|
principle |
Residual chlorine: electrode method PH: Glass electrode Turbidity: 90 ° light scattering method EC: Graphite 2 electrodes/4 electrodes (optional) Temperature: NTC |
|
|
Technical Specifications |
range |
Residual chlorine/chlorine dioxide: 0.0~5 (20) mg/L
Conductivity: 0~5000 us/cm |
|
unit |
Residual chlorine: mg/L pH:pH Turbidity: NTU
Conductivity/TDS: us/cm/mg/l |
|
|
accuracy |
Turbidity: ± 2% or ± 0.02NTU, whichever is higher in absolute value
Conductivity/TDS: ± 1% |
|
|
response time |
Less than 90 seconds (residual chlorine<2.5 minutes) |
|
|
Measurement Interval |
Continuous and periodic |
|
|
waterproof rating |
IP65 |
|
|
display screen |
7-inch touch color screen |
|
|
Overall dimensions |
Width: 25m |
|
|
input/output |
serial port output |
RS485, |
|
communication protocol |
Modbus |
|
|
GPRS |
optional |
|
|
wash |
Cleaning of residual chlorine electrode |
Manually wipe the platinum ring electrode regularly |
|
Pneumatic flushing requires a compressor (optional) |
||
|
Turbidity cleaning |
Manual regular flushing |
|
|
Automatic sediment discharge (optional) |
||
|
Installation requirements |
Installation location |
indoor |
|
auxiliary project |
220V power supply |
|
|
sample temperature |
5-40℃ |
|
|
Sample flow rate |
0.5~1.2L/min |
|
|
humidity |
<90% |
|

Runjin (Shenzhen) Environmental Technology Co., Ltd
Runjin (Shenzhen) Operation and Maintenance Center
Shenzhen Headquarters: No. 162 Shajiang Road, Xitou Community, Songgang Street, Bao'an District, Shenzhen, Guangdong Province (Building 2, Xinweirun High tech Park, 10th Floor, 1006)
Contact phone number: 19166393026
Kaiming KMW Water Quality Monitor Channel Cooperation Contact Number: 13828819385

Runjin Huanke WeChat official account

Channel distributors, please scan the code for consultation