Monitoring Plan for Drinking Water Terminal Quality (Secondary Water Supply)
Release date:2025-09-22

According to the requirements of the "Sanitary Standards for Drinking Water" for export water quality monitoring instruments, the company's pipeline water quality analysis system can measure turbidity, residual chlorine/chlorine dioxide, pH, EC, and temperature. It uses RS485 digital interface, TCP/IP, and GPRS/4G for wireless transmission. The ultra-low turbidity analyzer in this analysis system is equipped with a bubble removal device to ensure the accuracy of turbidity measurement; The residual chlorine measurement adopts a three electrode constant voltage residual chlorine electrode, which can achieve residual chlorine measurement of 0-20mg/L. There is no need to add electrolyte inside the electrode, and the maintenance workload is small. The pH value is detected by the glass electrode method; Detecting electrical conductivity in water using graphite two/four electrode method; The whole machine has the characteristics of small size, low maintenance, and low usage cost, making it suitable for situations with tight space.

3.1 Integration Plan
Based on the on-site conditions of the water supply network, our company will integrate drinking water quality monitoring products and develop a compact multi parameter water quality analysis system that can monitor turbidity, residual chlorine/chlorine dioxide in real time pH、 The five parameters of conductivity and temperature meet the requirements for routine measurement of drinking water.

 

System Features
All measurement, display, and transmission modules of the instrument are integrated into one box, with a volume of 250 * 400 * 550mm, occupying small space and easy installation;

Ø Electrode analyzer, the detection process does not require reagents, does not produce secondary pollution, and has a small maintenance workload;

Intelligent self diagnosis, with fault alarm functions such as water shortage and sensor device abnormalities;

Equipped with RS485 output and optional wireless network transmission;

Multi level permission management ensures data security;

Ø 7-inch industrial grade touch screen, making viewing and operation more convenient;


3.2 Technical Parameters

parameter

Technical Specifications

measurement parameters

pH, Turbidity, residual chlorine, EC/TDS、 temperature

principle

Residual chlorine: electrode method

PH: Glass electrode

Turbidity: 90 ° light scattering method

EC: Graphite 2 electrodes/4 electrodes (optional)

Temperature: NTC

Technical Specifications

range

Residual chlorine/chlorine dioxide: 0.0~5 (20) mg/L
Turbidity: 0-20NTU
pH:0- 14

Conductivity: 0~5000 us/cm
Temperature: 0-75 ℃

unit

Residual chlorine: mg/L

pH:pH

Turbidity: NTU

Conductivity/TDS: us/cm/mg/l
Temperature: ℃

accuracy

Turbidity: ± 2% or ± 0.02NTU, whichever is higher in absolute value
Residual chlorine: ± 0.02 mg/L (when the standard method detection value of actual water samples is ≤ 0.1 mg/L), measurement lower limit of 0.02 mg/l,<10% (when the standard method detection value of actual water samples is>0.1 mg/L)

Conductivity/TDS: ± 1%
pH: ± 0.1PH
Temperature: ± 0.2 º C;

response time

Less than 90 seconds (residual chlorine<2.5 minutes)

Measurement Interval

Continuous and periodic

waterproof rating

IP65

display screen

7-inch touch color screen

Overall dimensions

Width: 25m
Height: 55cm
Thickness: 40cm

input/output

serial port output

RS485,

communication protocol

Modbus

GPRS

optional

wash

Cleaning of residual chlorine electrode

Manually wipe the platinum ring electrode regularly

Pneumatic flushing requires a compressor (optional)

Turbidity cleaning

Manual regular flushing

Automatic sediment discharge (optional)

Installation requirements

Installation location

indoor

auxiliary project

220V power supply
Sampling point within 5 meters

sample temperature

5-40℃

Sample flow rate

0.5~1.2L/min

humidity

<90%


3.3 Installation and Use
Recommended for installation on indoor walls, the product is powered by 220VAC during use and requires continuous flow of water samples for measurement; Due to the fact that the electrode requires 12 hours of hydration (placed in a continuously flowing water body) before use, it is suitable for continuous use in tap water pipelines. This product does not require reagent replacement and requires minimal on-site maintenance. Therefore, handheld instruments need to be used for calibration during initial use to achieve high measurement accuracy;
Previous Return to List Next

Runjin (Shenzhen) Environmental Technology Co., Ltd

Runjin (Shenzhen) Operation and Maintenance Center

Shenzhen Headquarters: No. 162 Shajiang Road, Xitou Community, Songgang Street, Bao'an District, Shenzhen, Guangdong Province (Building 2, Xinweirun High tech Park, 10th Floor, 1006)

Contact phone number: 19166393026

Kaiming KMW Water Quality Monitor Channel Cooperation Contact Number: 13828819385

Scan
  • Runjin Huanke WeChat official account

  • Channel distributors, please scan the code for consultation

© 2024 RJ(SZ)Technology Co., Ltd. All rights reservedGuangdong ICP No. 2024229258