ZKAM-2000 (Type I) Continuous Monitoring System for Non Methane Total Hydrocarbons in Environmental Air
Based on the current emission standards of various industries in China and the environmental protection regulations implemented by the country, a new environmental air VOCs online monitoring system has been designed using multiple innovative technologies. The technical indicators comply with the requirements of the "Technical Regulations for Continuous Automatic Monitoring of Non Methane Total Hydrocarbons in Environmental Air (Trial)" (Zongzhanqi Zi [2021] No. 61), and the monitoring parameters are methane and non methane total hydrocarbons.

0755-29985935
Product principle
The instrument uses direct measurement method and built-in enrichment unit to measure ppb level non methane total hydrocarbons.
Product Features
The carrier gas, combustion gas, and combustion assisting gas are all controlled by electronic flow control. We have independently developed high-quality EPC and PID algorithm regulation, which has strong anti-interference ability and high control accuracy. The control accuracy can reach ± 0.01ml/min;
Adopting an intelligent chromatographic processing system, it has functions such as intelligent recognition, automatic recording, automatic diagnosis, automatic alarm, data acquisition, processing, display, storage, query and output of spectra;
The analyzer has various application designs such as conventional and explosion-proof, and can be applied to areas with different safety requirements;
Product parameters